Mimir First-Responder Manual - 20160419 V1.1 DPC
Executive Summary
- Respond to Alarms (& Alerts)
- Compressor calls First-Responder for help (email, txt)
- Wake up
- Determine Mimir Status and Electrical Power Status
- Did compressor recover on its own? (~minutes)
- How long has compressor been stopped?
- Short time (< 1 hr)
- Long time (> 1 hr)
- Vacuum status?
- Less than 10-4 torr = OK
- Between 10-4 and 10-3 torr
- If compressor < 1 hr off, OK
- If compressor > 1 hr off, Call Second-Responder
- Higher than 10-3 torr = Call Second-Responder
- Electrical Power Status – All 3-phases present?
- Re-Evaluate and Intervene or Call Second-Responder
- Get to Mesa
- Re-Evaluate Mimir Vacuum Status & Electrical Power Status
- If both OK, turn compressor on
- If Vacuum NOT OK, call Second-Responder
- If 3-Phase power not OK, wait…
- Report Actions
- Email to Dan Clemens about Status, Intervention
- Txt to Dan Clemens if Second-Responder called
- Problems beyond routine, CALL Dan Clemens (781-492-2726)
- Compressor calls First-Responder for help (email, txt)
...
- Temperature is 60 F
- Input (return) gas pressure is 100 psi
- Output (supply) gas pressure is 320 psi.
Compressor Status Web Page (Logger Webpage) under NORMAL operations
...