There are two sections in the page. The first section of this page
is the current values of the various inputs to the logger. The important
ones to look at here are the Fan, the Cold Head current, and the
Comp. Temp. If the compressor is not running the current values will be
zero or very close to zero.
NOTE: if the compressor temperature or Comp. Temp is above 105 this means
that the compressor is likely in a over temperature state. The compressor
must cool before a successful restart is possible.
...
The remote control section should appear as it does in this attached panel.
The main thing to notice is the state of the Compressor ROCB. This switch
is attached to a form C relay controlling the remote operation circuit breaker
or ROCB. When the switch is set to high that means that the relay is
energized and the breaker is in the on position. If it is in the low
position it just means that the relay is not energized and the ROCB
could be either in the on or off position.
Restarting the Compressor.
...